Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
Histomorphometric Analysis of Flaplessly Placed and Early Loaded One-Piece Mini Dental Implants in Overdenture Patients
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 42 , Issue 6
November/December 2022

Pages 761–768


Histomorphometric Analysis of Flaplessly Placed and Early Loaded One-Piece Mini Dental Implants in Overdenture Patients

Luc Van Doorne, MD, DDS/Gert Meijer, MD, DDS, PhD/Vincent Cuijpers, PhD/Hugo De Bruyn, DDS, PhD


PMID: 36305928
DOI: 10.11607/prd.6309

Mini dental implants (MDIs) are an affordable alternative for overdentures in medically compromised patients with reduced bone volume. This human study reports the histomorphometric analysis of early loaded and flaplessly placed tapered, one-piece MDIs (ILZ, Southern Implants; Sa: 1.5 μm) after 7 to 11 months in function. Patients agreed to have an additional MDI placed and removed for evaluation. MDI stability was assessed via Periotest prior to implant removal. Histologic sections of four mandibular and three maxillary MDIs with surrounding bone were processed, and the bone-to-implant contact (BIC) was analyzed. At retrieval, the MDIs were in function for more than 6 months, were clinically healthy, and had mean probing pocket depths of 1.4 mm and 1.6 mm in the maxilla and mandible, respectively. Periotest values were < 5.5, indicating clinical stability. Most of the screw threads were filled with bone and revealed an intimate BIC, without any signs of intervening fibrous tissue layer. In both arches, the mean BIC was 68.5%. Large osteocytes could be identified in the calcified tissue, indicative of mature peri-implant bone. It can be concluded that MDIs, when loaded within 2 weeks in either arch, provide proper clinical stability and high BIC after 6 months.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help